Open Rails - General Wagon Parameters

Aim - this section describes the basic standard physics parameters required to correctly define wagons and wagon functions in Open Rails Train Simulator.

If you wish to provide any feedback on this page, please use the contact page. It would be great to have some feedback as this helps to ensure the accuracy of the information and models.

Index

General Parameters

Carriage Steam Heating


Note: The default unit of measure (UoM) shown in the "Recommended Input Units" column is the UoM value that OR assumes if no UoM is included in the parameter statement.

ParameterENG or WAGDescriptionRecommended Input UnitsSuggested settingsNew or ExistingTypical Examples
General Parameters
ORTSNumberAxles ( x )WAGThe number of axles on the wagon.IntegerAs per wagon specifications.NewORTSNumberAxles ( 4 )
ORTSNumberBogies ( x )WAGThe number of bogies on the car.IntegerAs per wagon specifications.NewORTSNumberBogies ( 2 )
NumWheels ( x )WAGThis value is no longer required and has been superceded by the sum of ORTSNumberAxles and ORTSNumberDriveAxles. SuperceededDo not use.
ORTSLengthBogieCentre ( x )WAGDistance between the bogies.Distance - m, cm, mm, km, in, ft, in/2
Default - m
As per wagon specsNewORTSLengthBogieCentre ( 35ft )
ORTSLengthCarBody ( x )WAGDistance between the ends of the car (typically coupler pivot points).Distance - m, cm, mm, km, in, ft, in/2
Default - m
As per wagon specsNewORTSLengthCarBody ( 45ft )
ORTSLengthCouplerFace ( x )WAGDistance between coupler connection points.Distance - m, cm, mm, km, in, ft, in/2
Default - m
As per wagon specsNewORTSLengthCouplerFace ( 47ft )
ORTSWheelFlangeLength ( x )WAGWheel flange length is defined as the length of flange starting from the beginning of the maximum flange angle to the point where flange angle reduces to 26.6 degrees.Distance - m, cm, mm, km, in, ft, in/2
Default - m
As per wheel profile specsNewORTSWheelFlangeLength ( 1.0in )
ORTSMaximumWheelFlangeAngle ( x )WAGWheel flange angle is defined as the maximum angle of the wheel flange relative to the horizontal axis.Angle - deg, rad
Default - rad
As per wheel profile specsNewORTSMaximumWheelFlangeAngle ( 70deg )
Carriage Steam Heating
This section describe the parameters used to define steam heating if used on a train.
ORTSHeatingWindowDeratingFactor ( x )WAGDescribes the fraction of the car side that is occupied by windows. More heat loss ocurs through windows, then solid car sides.IntegerAs per wagon specifications.NewORTSHeatingWindowDeratingFactor ( 0.25 )
ORTSHeatingCompartmentTemperatureSet ( x )WAGThe temperature that the car thermostat is set to.Temperature - degf, degc
Default - degc
As per wagon specifications.NewORTSHeatingCompartmentTemperatureSet ( 18.3 )
ORTSHeatingCompartmentPipeAreaFactor ( x )WAGA factor that adjusts the heating area of the steam heater in the passenger compartmentIntegerAs per wagon specifications.NewORTSHeatingCompartmentPipeAreaFactor ( 3.0 )
ORTSHeatingTrainPipeOuterDiameter ( x )WAGOuter diameter of the main steam pipe that runs the length of the trainDistance - m, cm, mm, km, in, ft, in/2
Default - m
As per wagon specifications. is used to calculate standard resistance values.)NewORTSHeatingTrainPipeOuterDiameter ( 2.5in )
ORTSHeatingTrainPipeInnerDiameter ( x )WAGInner diameter of the main steam pipe that runs the length of the trainDistance - m, cm, mm, km, in, ft, in/2
Default - m
As per Wagon SpecsNewORTSHeatingTrainPipeInnerDiameter ( 2.0in )
ORTSHeatingConnectingHoseOuterDiameter ( x )WAGOuter diameter of the connecting hose between carriages.Distance - m, cm, mm, km, in, ft, in/2
Default - m
As per wagon specsNewORTSHeatingConnectingHoseOuterDiameter ( 2.05in )
ORTSHeatingConnectingHoseInnerDiameter ( x )WAGInner diameter of the connecting hose between carriages.Distance - m, cm, mm, km, in, ft, in/2
Default - m
As per wagon specsNewORTSHeatingConnectingHoseOuterDiameter ( 1.5in )
ORTSWagonSpecialType ( x )WAGSpecial use wagon.Text
HeatingBoiler = Steam heat boiler installed
Heated = Car is heated.
As per wagon specsNewORTSWagonSpecialType ( Heated )
ORTSHeatingBoilerWaterUsage ( x y )WAGWater usage for the steam heating boiler, and is a table with a series of x and y parametersx = steam usage (lb/hr) and y = water usage (g-uk/hr)As per wagon specsNewORTSHeatingBoilerWaterUsage ( )
ORTSHeatingBoilerFuelUsage ( x y )WAGFuel usage for the steam heating boiler, and is a table with a series of x and y parameters.x = steam usage (lb/hr) and y = water usage (g-uk/hr)As per wagon specsNewORTSHeatingBoilerFuelUsage ( )
ORTSHeatingBoilerWaterTankCapacity ( x y )WAGFeed water tank capacity for the steam boilerVolume - ft^3, in^3, m^3, l, g-uk, g-us, gal, gals
Default - l
As per wagon specsNewORTSHeatingBoilerWaterTankCapacity ( 1500 )
ORTSHeatingBoilerFuelTankCapacity ( x y )WAGFuel tank capacity for the steam heating boiler. Applies to steam heating boiler cars only.Volume - ft^3, in^3, m^3, l, g-uk, g-us, gal, gals
Default - l
As per wagon specsNewORTSHeatingBoilerFuelTankCapacity ( 800g-uk )

top